justin_o_guy2
Serious Thumper
Offline
What happened?
Posts: 55279
East Texas, 1/2 dallas/la.
|
I know youve readily admitted your lack of ability in the electrical department. I totally understand. I dont like messing with that styuff either & Im far from a pro at it. Ive seen guys I swear they could see the juice flowin in the wires & knew right where the problem was.. Thats not me, but, the only way to win is, either have a good memory & not get confused or use a notebook, start checking for power in places you know its supposed to be, Check grounds, I like the notebook so that if I dont win quick I can walk away & come back & not have to start over.
The AF taught the 1/2 split troubleshooting method. Check signal at source, check signal where its supposed to be. If its not there, go 1/2 way back to source & check. If its not there, go back another 1/2 way, if it is, go forward 1/2 way, check, It'll hunt down pretty quick that way, A test lite & an ohm meter & a notebook & wiring diagram & youll win,.
|